CVE-2026-64629 1 Siemens 1 Parasolid 2026-11-10 7.8 High
A vulnerability has been identified in Parasolid V38.0 (All versions < V38.0.235), Parasolid V38.1 (All versions < V38.1.230), Simcenter Femap (All versions < V2606.0002). The affected applications contains an out of bounds read vulnerability while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
CVE-2026-59082 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected devices implicitly execute active content when opening files. This could allow an attacker to make the user execute arbitrary code on the device.
CVE-2026-58115 1 Siemens 1 Simatic Iot2050 2026-11-10 10 Critical
A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.
CVE-2026-58114 2026-11-10 7.5 High
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Runtime Professional V20 (All versions), SIMATIC WinCC Runtime Professional V21 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SIMATIC WinCC V8.1 (All versions). Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC.
CVE-2025-40759 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2025-40742 2026-11-10 5.3 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions < V11.0), SIPROTEC 5 7KE85 (CP300) (All versions < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.91), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA86 (CP300) (All versions < V11.0), SIPROTEC 5 7SA87 (CP300) (All versions < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions < V8.91), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD86 (CP300) (All versions < V11.0), SIPROTEC 5 7SD87 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ86 (CP300) (All versions < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions < V8.91), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP300) (All versions < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions < V8.91), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP300) (All versions < V11.0), SIPROTEC 5 7SL87 (CP300) (All versions < V11.0), SIPROTEC 5 7SS85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions < V8.91), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT86 (CP300) (All versions < V11.0), SIPROTEC 5 7UT87 (CP300) (All versions < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions < V11.0), SIPROTEC 5 7VK87 (CP300) (All versions < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access.
CVE-2024-54678 1 Siemens 13 Simatic Pcs Neo, Simatic S7-plcsim, Simatic Step 7 and 10 more 2026-11-10 8.2 High
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2024-49849 2026-11-10 7.8 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
CVE-2026-12574 1 Zohocorp 1 Ddi Central 2026-11-10 8.1 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to Server-side HTML/JavaScript injection in analytics PDF generation leading to local file disclosure.
CVE-2026-125709 1 Redhat 4 Enterprise Linux, Hummingbird, Openshift and 1 more 2026-11-10 4.2 Medium
A flaw was found in libstdc++. When a byte-by-byte write operation fails during file stream processing, the library may still append data into the internal memory buffer. An attacker capable of inducing repeated write failures in an affected service can trigger a buffer overflow, potentially resulting in a Denial of Service (DoS) or memory corruption.
CVE-2026-125707 1 Redhat 2 Enterprise Linux, Rhel Els 2026-11-10 6.1 Medium
A flaw was found in GStreamer's MXF demuxer. When an application processes a crafted MXF file, an off-by-one bounds check can allow a one-byte write past the logical end of a temporal offset array. This may corrupt memory and cause the application to crash. The extent of the impact has not been demonstrated by a runtime test.
CVE-2026-125706 1 Redhat 2 Enterprise Linux, Rhel Els 2026-11-10 5.5 Medium
A flaw was found in GStreamer's gst-plugins-bad MPEG Program Stream demuxer and resindvd DVD-playback plugin. The PES header parsers do not adequately check remaining data before reading timestamps and optional header fields. Opening a specially crafted MPEG Program Stream file can cause an out-of-bounds read and potentially crash the application, resulting in a denial of service.
CVE-2026-12573 1 Zohocorp 1 Ddi Central 2026-11-10 8.8 High
Zoho Corporation ManageEngine DDI Central versions 6200 and below are vulnerable to Cisco IOS command injection via DHCP pool name leading to arbitrary commands on managed Cisco routers.
CVE-2026-125715 2026-11-10 5.3 Medium
Samsung mTower lacks access control for TA sessions, allowing a Normal World application to open TA sessions and invoke their commands, or use a close existing sessions if thier identifiers are known, The impact depends on the affected TA.
CVE-2026-123717 2026-11-10 N/A
OS command injection in the pass and bitwarden credential providers in Eclipse Foundation Eclipse Otterdog through 1.7.1 allows a user able to modify an organization configuration to execute arbitrary commands with the privileges of the operator running otterdog, including access to their credential vault, via a crafted secret reference (pass:<path> or bitwarden:<item>@<field>) or credential identifier that is resolved when otterdog apply is run.
CVE-2026-12572 1 Zohocorp 1 Ddi Central 2026-11-10 7.2 High
Zoho Corporation ManageEngine DDI Central version below 6201 is vulnerable to SQL injection in HA replication username handling leading to command execution as the PostgreSQL service account.
CVE-2026-125672 1 Redhat 2 Enterprise Linux, Rhel Els 2026-11-10 6.6 Medium
A flaw was found in cockpit-storaged. A Tang keyserver address read from a clevis token in a LUKS header is concatenated into curl's argument vector without a "--" separator. An address beginning with "-" is parsed by curl as an option instead of a hostname, allowing an attacker who can attach a crafted LUKS/clevis block device (for example, a local unprivileged user with an active console or desktop login session) to have an administratively-privileged Cockpit user unknowingly trigger curl option injection when editing the device's Tang keyserver settings. This can lead to arbitrary file read or write as the Cockpit session user.
CVE-2026-112323 2 Red Hat, Redhat 5 Enterprise Linux, Enterprise Linux, Hardened Images and 2 more 2026-11-10 7.5 High
The AUTH_GSSAPI handler in lib/rpc/svc_auth_gssapi.c in MIT Kerberos 5 (aka krb5) 1.5.2 and later allows remote attackers to cause a denial of service (memory exhaustion in kadmind) by sending repeated failed AUTH_GSSAPI_INIT requests. Each failed request allocates client state that is only freed after a 15-minute expiration timeout, allowing an attacker to accumulate memory faster than it is reclaimed.
CVE-2026-119079 2 Red Hat, Redhat 5 Enterprise Linux, Enterprise Linux, Hardened Images and 2 more 2026-11-10 7.5 High
decode_sequence_of() in lib/krb5/asn.1/asn1_encode.c in MIT Kerberos 5 (aka krb5) 1.11 and later grows the decoded element array one entry at a time, which allows remote attackers to cause a denial of service (CPU consumption in the KDC) by sending an unauthenticated AS-REQ or TGS-REQ with a large number of elements in a SEQUENCE OF field over TCP.
CVE-2026-95651 1 Zohocorp 1 Ddi Central 2026-11-10 7.5 High
Zoho Corporation ManageEngine DDI Central versions 6500 and below are vulnerable to an unauthenticated GSS-TSIG keytab update vulnerability in the Linux Node Agent.