Search Results (2564 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-0225 2026-04-15 4.3 Medium
A vulnerability classified as problematic was found in Tsinghua Unigroup Electronic Archives System 3.2.210802(62532). Affected by this vulnerability is an unknown functionality of the file /setting/ClassFy/exampleDownload.html. The manipulation of the argument name leads to path traversal: '/../filedir'. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2024-41336 2026-04-15 7.5 High
Draytek devices Vigor 165/166 prior to v4.2.6 , Vigor 2620/LTE200 prior to v3.9.8.8, Vigor 2860/2925 prior to v3.9.7, Vigor 2862/2926 prior to v3.9.9.4, Vigor 2133/2762/2832 prior to v3.9.8, Vigor 2135/2765/2766 prior to v4.4.5.1, Vigor 2865/2866/2927 prior to v4.4.5.3, Vigor 2962/3910 prior to v4.3.2.7, Vigor 3912 prior to v4.3.5.2, and Vigor 2925 up to v3.9.6 were discovered to store passwords in plaintext.
CVE-2025-3364 1 Hgiga 1 Powerstation 2026-04-15 6.7 Medium
The SSH service of PowerStation from HGiga has a Chroot Escape vulnerability, allowing attackers with root privileges to bypass chroot restrictions and access the entire file system.
CVE-2025-32802 1 Redhat 1 Enterprise Linux 2026-04-15 6.1 Medium
Kea configuration and API directives can be used to overwrite arbitrary files, subject to permissions granted to Kea. Many common configurations run Kea as root, leave the API entry points unsecured by default, and/or place the control sockets in insecure paths. This issue affects Kea versions 2.4.0 through 2.4.1, 2.6.0 through 2.6.2, and 2.7.0 through 2.7.8.
CVE-2025-2500 2026-04-15 7.4 High
A vulnerability exists in the SOAP Web services of the Asset Suite versions listed below. If successfully exploited, an attacker could gain unauthorized access to the product and the time window of a possible password attack could be expanded.
CVE-2025-24852 2026-04-15 4.6 Medium
Storing passwords in a recoverable format issue exists in CHOCO TEI WATCHER mini (IB-MCT001) all versions. If this issue is exploited, an attacker who can access the microSD card used on the product may obtain the product login password.
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2025-23008 1 Sonicwall 1 Netextender 2026-04-15 7.2 High
An improper privilege management vulnerability in the SonicWall NetExtender Windows (32 and 64 bit) client allows a low privileged attacker to modify configurations.
CVE-2025-23009 1 Sonicwall 1 Netextender 2026-04-15 7.2 High
A local privilege escalation vulnerability in SonicWall NetExtender Windows (32 and 64 bit) client which allows an attacker to trigger an arbitrary file deletion.
CVE-2025-22368 2026-04-15 N/A
The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-22367 2026-04-15 N/A
The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-22366 2026-04-15 N/A
The authenticated firmware update capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2025-1977 1 Moxa 2 Nport 6100-g2 Series, Nport 6200-g2 Series 2026-04-15 N/A
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.
CVE-2025-0280 1 Hcltech 1 Compass 2026-04-15 7.5 High
A security vulnerability in HCL Compass can allow attacker to gain unauthorized database access.
CVE-2025-23181 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2025-23180 2026-04-15 8 High
CWE-250: Execution with Unnecessary Privileges
CVE-2025-1394 1 Silabs 1 Emberznet 2026-04-15 N/A
The Ember ZNet stack’s packet buffer manager may read out of bound memory leading to an assert, causing a Denial of Service (DoS).
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).