Export limit exceeded: 24479 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (24479 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2025-2367 | 2026-04-15 | 6.3 Medium | ||
| A vulnerability has been found in Oiwtech OIW-2431APGN-HP 2.5.3-B20131128 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formScript of the component Personal Script Submenu. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-43654 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43655 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43656 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43657 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2024-43688 | 2 Openbsd, Vixie | 2 Openbsd, Cron | 2026-04-15 | 7.3 High |
| cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring. | ||||
| CVE-2024-43778 | 1 Takenaka Engineering | 9 Ahd04t-a Firmware, Ahd08t-a Firmware, Ahd16t-a Firmware and 6 more | 2026-04-15 | 8.8 High |
| OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings. | ||||
| CVE-2025-22495 | 2026-04-15 | 8.4 High | ||
| An improper input validation vulnerability was discovered in the NTP server configuration field of the Network-M2 card. This could result in an authenticated high privileged user having the ability to execute arbitrary commands. The vulnerability has been resolved in the version 3.0.4. Note - Network-M2 has been declared end-of-life in early 2024 and Network-M3 has been released as a fit-and-functional replacement. | ||||
| CVE-2025-68459 | 1 Ruijie | 3 Ap180, Ap180-ac, Ap180-pe | 2026-04-15 | 7.2 High |
| RG - AP180, Indoor Wall Plate Wireless AP AP180 series provided by Ruijie Networks Co., Ltd. contain an OS command injection vulnerability. An arbitrary OS command may be executed on the product by an attacker who logs in to the CLI service. | ||||
| CVE-2024-45242 | 1 Engeniustech | 1 Enh1350ext Firmware | 2026-04-15 | 7.8 High |
| EnGenius ENH1350EXT A8J-ENH1350EXT devices through 3.9.3.2_c1.9.51 allow (blind) OS Command Injection via shell metacharacters to the Ping or Speed Test utility. During the time of initial setup, the device creates an open unsecured network whose admin panel is configured with the default credentials of admin/admin. An unauthorized attacker in proximity to the Wi-Fi network can exploit this window of time to execute arbitrary OS commands with root-level permissions. | ||||
| CVE-2025-10451 | 1 Insyde | 1 Insydeh2o | 2026-04-15 | 8.2 High |
| Unchecked output buffer may allowed arbitrary code execution in SMM and potentially result in SMM memory corruption. | ||||
| CVE-2024-45251 | 1 Elsight | 1 Halo Firmware | 2026-04-15 | 9.8 Critical |
| Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | ||||
| CVE-2024-45252 | 1 Elsight | 1 Halo Firmware | 2026-04-15 | 9.8 Critical |
| Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') | ||||
| CVE-2025-22368 | 2026-04-15 | N/A | ||
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. | ||||
| CVE-2024-45288 | 1 Freebsd | 1 Freebsd | 2026-04-15 | 8.4 High |
| A missing null-termination character in the last element of an nvlist array string can lead to writing outside the allocated buffer. | ||||
| CVE-2024-45320 | 2026-04-15 | N/A | ||
| Out-of-bounds write vulnerability exists in DocuPrint CP225w 01.22.01 and earlier, DocuPrint CP228w 01.22.01 and earlier, DocuPrint CM225fw 01.10.01 and earlier, and DocuPrint CM228fw 01.10.01 and earlier. If an affected MFP processes a specially crafted printer job file, a denial-of-service (DoS) condition may occur. | ||||
| CVE-2025-22367 | 2026-04-15 | N/A | ||
| The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS. | ||||
| CVE-2024-4696 | 1 Lenovo | 1 Service Bridge | 2026-04-15 | 7.5 High |
| A privilege escalation vulnerability was reported in Lenovo Service Bridge prior to version 5.0.2.17 that could allow operating system commands to be executed if a specially crafted link is visited. | ||||
| CVE-2024-47133 | 1 Iodata | 2 Ud-lt1\/ex Firmware, Ud-lt1 Firmware | 2026-04-15 | N/A |
| UD-LT1 firmware Ver.2.1.9 and earlier and UD-LT1/EX firmware Ver.2.1.9 and earlier allow a remote authenticated attacker with an administrative account to execute arbitrary OS commands. | ||||